Warm Water Underfloor Heating Manifolds 

Manifolds for warm water underfloor heating systems.

Untitled Button
Brass Nickel with Temp Gauge & Ball Valves

Brass Nickel Manifold with Temp Gauge & Ball Valves

  • from £84.14
Stainless Steel with Temp Gauge & Ball Valves

Stainless Steel Manifold with Temp Gauge & Ball Valves

  • from £79.90
Eurocones Multi/PE

Eurocones Multi/PE

  • from £1.33
Manifold Extension Piece (NEEDS EUROS)

Manifold Extension Piece (NEEDS EUROS)

  • £48.59

Frequently Asked Questions

What our customers most commonly ask us about

  • What is a manifold and why do I need one for my underfloor heating system?
  • A manifold is the central distribution point for your warm water underfloor heating system. It connects your boiler or heat source to the individual heating circuits in your floor. The manifold allows you to balance the flow through each circuit, purge air from the system and control which zones are active. Each heating circuit connects to the manifold via specialist pipes and the manifold typically includes flow gauges, thermostatic valves and air vents to ensure optimal system performance.
  • What's the difference between brass nickel and stainless steel manifolds?
  • Both our brass nickel and stainless steel manifolds function similarly, but offer different benefits. Brass nickel manifolds are more cost-effective while still providing excellent durability and heat distribution. Stainless steel manifolds offer superior corrosion resistance, making them ideal for installations in more challenging environments. Both options work perfectly with our pumps & valves and include temperature gauges and ball valves for comprehensive system control.
  • How many ports do I need on my manifold?
  • The number of ports required depends on the size and layout of your installation. Each heating circuit requires one port, and we typically recommend limiting circuit lengths to 80-100m of pipe to maintain efficient heat distribution. For larger rooms, multiple circuits may be needed. For example, a 20m² room might need two circuits, requiring two ports on your manifold. Our manifolds are available with different numbers of ports to suit various project sizes, and extension pieces can be added if your requirements change.
  • Do I need to house my manifold in a cabinet?
  • While not strictly necessary, housing your manifold in a cabinet provides a neater, more professional finish and protection for the components. Manifolds are typically installed in accessible locations such as utility rooms, cupboards, or hallways, and should be positioned to allow easy access for maintenance and adjustments. The manifold should be mounted on a solid wall with sufficient space for controls & wiring connections. If aesthetics are important, especially in visible locations, a dedicated cabinet is recommended.
  • Can I add more heating zones to my existing manifold system?
  • Yes, our systems are designed to be expandable. If you already have a manifold installed and wish to add more heating zones, you have several options. You can either replace your existing manifold with one that has more ports, or add manifold extension pieces to your current setup. When expanding your system, you'll also need additional loops of pipe and potentially supplementary insulation & overlay materials for the new areas. Each additional heating zone can be controlled independently, giving you greater flexibility over your heating system.