Electric Underfloor Heating
for a Lounge Retrofit
With a cold lounge in an older semi-detached home requiring a modern, efficient heating solution, Rayotec delivered a low-profile electric underfloor heating installation — minimal floor height rise, maximum coverage, completed in just 2 days.
The Challenge
Retrofitting electric underfloor heating into an older property requires careful assessment before any work begins. Rayotec carried out a site visit to evaluate the existing subfloor condition, understand the layout, and advise the client on the best approach — particularly important here, as the lounge had been cold and the subfloor condition was not ideal.
The project also required careful coordination with other trades working to a shared schedule. The client’s priorities were clear from the outset:
- Achieve maximum mat coverage in the lounge for even, consistent heat distribution throughout a cold room
- Keep floor height rise to an absolute minimum given the existing room constraints
- Install a smart WiFi thermostat for remote control and scheduling from a smartphone
- Work efficiently around other trades to keep the project on schedule
- Recommend improvements to the subfloor where needed, to give the system the best possible base
The Rayotec Solution
Rayotec specified a Rayomax 150W/m² heating mat system paired with 6mm Rayoboards — the slimmer board chosen deliberately to keep the floor height increase as low as possible while still delivering effective insulation performance. This combination ensured the system would be both efficient and practical within the constraints of the existing room.
During the site visit, the subfloor condition was assessed and recommendations were made to the client regarding potential improvements — any preparation work carried out ahead of the installation was the responsibility of the client and their chosen contractors. Mat coverage areas were walked through with the client in detail to confirm the layout met their requirements, and thermostat locations were agreed together before any work began. Rayotec also advised the client on what first fix electrical work was needed in advance, as the team was engaged for second fix only — ensuring a smooth, uninterrupted installation on the day.
Throughout the project, Rayotec worked flexibly around the programme of other trades, completing the electrics on day one and the full system installation on day two with minimal mess and disruption.
The Result
The client was delighted with the finished system. Even heat distribution across the lounge, a floor height rise of just 8mm, and a smart WiFi thermostat providing remote scheduling and control — all delivered in two days with minimal disruption.
The 6mm Rayoboards kept the build-up as slim as possible without compromising insulation performance, directing heat upward effectively and reducing running costs. The engineered wood floor was then floated directly over the system, with Rayotec leaving a clean, ready-to-finish surface for the floor layer.
Why Older Properties Require a Careful Approach
Retrofitting underfloor heating into an older home brings a specific set of challenges — subfloors that may be uneven or in poor condition, rooms that have been cold for years, and the need to coordinate carefully around other trades. Getting the specification right from the outset is essential.
Electric systems are particularly well suited to these situations: no boiler upgrades, no pipework, and no wet trades. With the right insulation, a thorough site assessment, and a methodical installation, electric underfloor heating can transform even the coldest room quickly and cleanly.
How the Installation Came Together
The full installation was completed in two days — second fix electrics on day one, system installation on day two, ready for the engineered wood floor fitter to follow.
Rayotec was engaged for second fix electrics only, with the client advised during the site visit on exactly what first fix work was required in advance. All electrical connections were completed on day one, with thermostat back-box positions confirmed with the client to minimise chasing. Getting the electrics right first ensures a clean, uninterrupted installation of the heating system to follow.
Electrical connections completed and thermostat locations confirmed with the client
The subfloor was thoroughly cleaned before any boards were laid. Given the age of the property and the variable condition of the substrate — noted during the site visit — any subfloor improvements recommended prior to the installation were the responsibility of the client. A clean, well-prepared subfloor gives the system the best possible base for long-term performance.
Lounge subfloor cleaned and prepared ready for boarding
6mm Rayoboards were loose-laid throughout the lounge — the slim profile chosen to keep the total floor height rise to just 6mm while still delivering effective insulation performance. Boards were taped at the joins throughout to hold the layout securely in place. Loose laying the boards at this stage allows for quick, precise coverage across the full room before the heating mats are positioned, and keeps the overall build-up as clean and controlled as possible.
6mm Rayoboards loose-laid throughout the lounge for a minimal floor height rise
Rayomax 150W/m² heating mats were laid methodically across the lounge, with coverage planned in advance — agreed with the client during the site visit — to maximise the effective heated area and deliver even heat distribution throughout a room that had struggled to stay warm. The mat was tested to ensure it was functioning after being laid.
Rayomax 150W mats installed across the lounge for maximum even coverage
With the heating mats in place and electrically verified, the system was left ready for the engineered wood floor to be floated directly over. Smart WiFi thermostats were fitted and commissioned, with manuals sent over explaining how to use the thermostat. Rayotec handed over a clean, complete installation — ready for the floor fitter to follow without delay.

System installed and commissioned — ready for engineered wood to be floated over
Can electric underfloor heating be retrofitted into an older property?
Yes — with the right assessment and preparation it can be done cleanly and efficiently. Electric systems require no pipework or boiler modifications, making them ideal for retrofit work. A site visit is important in older properties to evaluate the subfloor condition and advise on the best specification before any work begins.
Why use 6mm Rayoboards rather than thicker alternatives?
Where floor height is a concern — as it was here — 6mm Rayoboards offer an effective insulation solution while keeping the total build-up to an absolute minimum. They direct heat upward into the room efficiently, reducing warm-up times, and are an excellent choice when space is tight.
Is electric underfloor heating compatible with engineered wood flooring?
Yes. Engineered wood is well suited to electric underfloor heating and is one of the most popular floor finishes used with UFH systems. It offers good thermal conductivity while accommodating the slight movement that can occur with temperature changes, making it a reliable and attractive choice.
How does a smart WiFi thermostat benefit an electric UFH system?
Smart thermostats allow room-by-room scheduling and remote control via smartphone — meaning the system can be pre-heated or adjusted from anywhere. Combined with the insulation performance of Rayoboards, this makes for a genuinely efficient, responsive, and easy-to-manage heating system.
Ready to upgrade your home heating?
Rayotec installs electric underfloor heating across Surrey and the surrounding area — for retrofits, refurbishments, new builds, and extensions.